Detalles esenciales
Cantidad (piezas):270
Volumen:0 m³
MOQ:10
Peso bruto:0 kg
Tiempo de entrega:4-6weeks
Tamaño:L(6.5)*W(1.03)*H(5.2) cm
Peso neto:0 kg
Envío:快递
número de especificación:EVKR10-40-B
Número de producto:EVKR10-40-B
Descripción del paquete:无
Introducción del producto
· Volts 1000Vdc
· Amps 40A
· Max breaking capacity 20kA
· Min breaking capacity 300% of rated current
Standard (reference) GB/T31465, ISO8820
Pre-acting I²t (A²s) 1027
Total I²t (A²s) 3080
Power Loss at In (W) 13.1
Power Loss at 0.5xIn (W) 2.2
Detalles del producto

Features
• Higher voltage rating provides overall system efficiency using smaller, more economical conductors while
meeting the needs of higher voltage battery packs.
• Higher interrupting rating protects high capacity battery packs needed for vehicle acceleration and range
requirements.
Transportation
During transportation, it shall be rainproof, moisture-proof to avoid severe ground vibration and impact.
Temperature
Normal condition -5℃~40℃
Allowed condition (Derating) -40℃~100℃
During the rated current test of the fuse, it shall be separately installed in the natural air without ventila-
tion, and there shall be no other heating parts or heat dissipation parts within 1m except the connecting
wires. When the fuse operates above 20℃ , the rated current needs additional correction.
Altitude
Allowed condition (Derating) 2000-5000m
Parameter correction of altitude change: higher altitude mainly leads to insulation deterioration, heat dissi-
pation condition deterioration and air pressure change.